BRESSNER Technology GmbH - Logo

Digi One® series

Cost-efficient serial-to-Ethernet device server in a compact design

FEATURES

  • Serial-to-Ethernet device server
  • 1x RS-232/422/485
  • 10/100Base-T Ethernet
  • Patented RealPort® for COM/TTY connections
  • TCP/UDP socket services
SKU: 27800

Description

Digi One® series – Compact serial servers for simple data communication

The Digi One® Series provides a reliable and cost-effective way to connect any type of serial device to Ethernet. With its compact design, it combines cost-effective performance and capabilities in one of the smallest form factors available.

Flexible protocol support for optimal connectivity

The Digi One® Series supports a variety of protocols, including serial tunneling, TCP/UDP connections and Digi’s patented RealPort® COM port redirector for native remote COM port access. RealPort allows existing applications to communicate seamlessly with serial devices over Ethernet as if they were connected via a serial cable.

Easy installation and configuration

Installation of the Digi One® is a breeze, both locally and remotely. The IP address can be configured via DHCP, ARP ping or the Device Discovery Utility, which automatically detects all Digi One devices on the network. The user-friendly web interface also allows users to configure advanced features according to their requirements.

Experience the ease of data communication with the Digi One® series and enjoy seamless integration of your serial devices into your Ethernet network.

Specifications

Digi One® SP Digi One® SP IA Digi One® IA Digi One® IAP
FEATURES
Management HTTP configuration HTTP configuration HTTP configuration, Digi Port Authority – Remote management diagnostics and auto-discovery tool HTTP configuration, Digi Port Authority–Remote management diagnostics and auto-discovery tool, SNMP (read/write)
Protocols TCP/UDP Socket Services, UDP Multicast, Telnet, Reverse Telnet, RFC2217, DHCP/RARP/ARP-Ping for IP address assignment TCP/UDP Socket Services, UDP Multicast, Telnet, Reverse Telnet, RFC2217, DHCP/RARP/ARP-Ping for IP address assignment Telnet, Reverse Telnet and extended Telnet RFC 2217; TCP/UDP Socket Services; UDP, support 32 concurrent socket connections; DHCP/RARP, ARP-Ping; Modbus ASCII/RTU to Modbus TCP conversion; Modbus Ethernet-to-Serial Bridge Function supporting Modbus/TCP, Modbus/UDP, Modbus/RTU, Modbus/ASCII; Modbus bridge supports TCP and UDP Encapsulation of Modbus/RTU, Modbus/ASCII Telnet, Reverse Telnet, RFC2217, TCP/UDP Socket Services, PPP, DHCP/RARP, ARP-Ping, Static IP for IP address assignment, Support for 64 concurrent socket connections, ASCII, Modbus RTU/ASCII, Modbus/TCP
Software Patented RealPort COM port redirector for COM/TTY ports Patented RealPort® for COM/TTY ports Patented RealPort COM port redirector for COM/TTY ports for Microsoft® Windows®, UNIX® and Linux® Patented RealPort COM port redirector for COM/TTY ports for Microsoft® Windows®, UNIX® and Linux®
Security SSHv2, SSL, TLS, HTTPS
Operating system Microsoft Windows® 7, 8, 8.1, 10 and Windows Server® 2012, 2016, 2019; and Linux®. Note: TCP/UDP socket services are operating system independent Microsoft Windows® 7, 8, 8.1, 10 and Windows Server® 2012, 2016, 2019; and Linux®
Note: TCP/UDP socket services are operating system independent
AIX, HP-UX, Solaris, Linux®, Windows® 2000, Windows® XP, Windows® 7, Windows® 8, Windows® 8.1, Windows® 10, Windows Server® 2003, Windows Server® 2008, Windows Server® 2012. Note: TCP/UDP socket services are operating system independent Linux®, Windows® 2000, Windows® XP, Windows® 7, Windows® 8, Windows® 8.1, Windows® 10, Windows Server® 2003, Windows Server® 2008, Windows Server® 2019, Windows Server® 2016, Windows Server® 2012. Note: TCP/UDP socket services are operating system independent.
Status LEDs Power, Ethernet link and activity Link, Power Serial signals, Power, Ethernet, Diagnostics Serial signals, Power, Ethernet and diagnostics
Dimensions (L x W x T) 9.40 cm x 4.30 cm x 2.30 cm (3.70 in x 1.72 in x 0.93 in) 9.40 cm x 4.30 cm x 2.30 cm (3.70 in x 1.72 in x 0.93 in) 12.00 cm x 2.30 cm x 10.10 cm (4.70 in x 0.90 in x 4.0 in) 12.00 cm x 2.30 cm x 10.10 cm (4.70 in x 0.90 in x 4.0 in)
Weight 65.00 g (2.29 oz) 65.00 g (2.29 oz) 64.00 g (2.25 oz) 64.0 g (2.5 oz)
Other Full modem and hardware flow control, modem emulation, wall mount kit (optional) Full modem and hardware flow control, Modem emulation, DIN rail and wall mount kit included Full modem and hardware flow control, Flash upgradeable firmware, 35 mm DIN rail mounting IAP: Full modem and hardware flow control, Flash upgradeable firmware, 6 ms serial over Ethernet latency, 35 mm DIN rail mounting
IAP Haz: Conformal coated PCB, Full modem and hardware flow control, Flash upgradeable firmware, 6 ms serial over Ethernet latency, 35 mm DIN rail mounting
INTERFACES
Serial ports 1x RS-232/422/485 (switch selectable) 1x RS-232/422/485 (switch selectable) 1x RS-232/422/485 (switch selectable) 1x RS-232/422/485 (switch selectable)
Serial connector DB-9M DB-9M DB-9M or screw terminal connectors Screw terminal connector or DB-9M; DB-9M can act as a second direct RS-232 port or can be used as a pass-through port for the screw terminal connector
Serial throughput Up to 230 Kbps Up to 230 Kbps Up to 230 Kbps Up to 230 Kbps
Ethernet physical layer 10/100Base-T 10/100Base-T 10/100Base-T 10/100Base-T
POWER REQUIREMENTS
Power input 9-30 VDC @ 0.5 Amps max 9-30 VDC @ 0.5 Amps max 9-30 VDC @0.5 Amps max 9 – 30 VDC @ 0.5 Amps max
Power supply 12 VDC / 1.5 A max out; 100-240 VAC 50-60 Hz in (wall mount) 12 VDC/1.5A max out; 100-240 VAC 50-60 Hz in (wall mount) Screw terminal block power jack for external supply Removable screw terminal for power (power supply not included)
Powered Ethernet IAP: 802.3af (midspan and endspan) support and fail-over capability when used with 9-30 VDC input
IAP Haz: N/A
Power consumption Typical: 4 W; Max: 6 W Typical: 4 W; Max: 6 W
Product surge protections 4 kV burst (EFT) per EN61000-4-4, 2 kV surge transient per EN61000-4-5 4 kV burst (EFT) per EN61000-4-4, 2 kV surge transient per EN61000-4-5 when used with supplied power adapter 2 kV isolation between power supply and serial ground product 2 kV isolation between power supply and serial ground product when used with Digi power supply
Power connector Bare-wire “pigtail” power connector
ENVIRONMENTAL
Operating temperature 10º C to 45º C (50º F to 113º F) 10º C to 45º C (50º F to 113º F) 0º C to 60º C (32º F to 140º F) IAP: 0° C to +60° C (32° F to +140° IAP Haz: -35° C to +74° C (-31° F to +165° F)
Relative humidity 5% to 90% (non-condensing) 5% to 90% (non-condensing) 5% to 90% (non-condensing) 5% to 90% (non-condensing)
Ethernet isolation 1500 VAC min per IEEE 802.3/ANSI X3.263 1500 VAC min per IEEE 802.3/ANSI X3.263
Serial port protection (ESD) 15 kV human body model 15 kV human body model
REGULATORY APPROVALS
Safety UL 60950, EN60950, CAN/CSA C22.2 No.60950 UL 60950, EN60950, CAN/CSA C22.2 No.60950 UL 60950, UL1604 (Class 1 Div 2), EN60950, CAN/CSA C22.2 No.60950 UL 1950, UL 1604 (Class 1, Div. 2), CSA 22.2 No 950, EN60950
Emissions / Immunity FCC Part 15 Subpart B (Class A), EN55024, EN55022 (Class A), EN61000-3-2,3 FCC Part 15 Subpart B (Class A), EN55024, EN55022 (Class A), EN61000-3-2,3 FCC Part 15 Subpart B (Class A), EN55024, EN55022 (Class A), EN61000-6-2 FCC Part 15 (Class A), ICES-003 (Class A), CE, AS3548, EN6100-6-2 + EN55024, EN55022 (Class A)

Documents

Digi One® SP Datasheet
Digi One® SP IA Datasheet
Digi One® IA Datasheet
Digi One® IAP Datasheet

Order information

Product information Digi One® series
DIGI ONE®
70001851 Digi One® SP: Serial-to-Ethernet device server
– 1x RS-232/422/485 DB-9 port
– Patented RealPort® for COM/TTY port control and management
– TCP/UDP socket services
70001999 Digi One® SP IA: Serial-to-Ethernet device server for industrial automation
– 1x RS-232/422/485 DB-9 port
– DIN rail and wall mount kits
– TCP/UDP socket services
70001862 Digi One® IA: Device server with 1x RS-232/422/485 port (selectable by switch)
– Modbus serial to Modbus/TCP protocol conversion
– Industrial protocol support
70001777 Digi One® IAP: Device server with 1x RS-232/422/485 port (selectable by switch)
– DIN rail mounting optional
– Multi-protocol conversion
– Suitable for hazardous areas

Customers were also interested in